CPU: Dual Socket P4 (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors
Core Count: Up to 40C/80T’ Up to 60MB Cache per CPU
Note: Supports up to 270W TDP CPUs (Air Cooled)* *Air Cooled CPUs with TDP over 205W only supported under specific conditions. Contact a Supermicro representative for details.
Max GPU Count: Up to 2 single-width GPU(s)
Supported GPU: NVIDIA PCIe: L4, A2 Intel PCIe: Intel Data Center GPU Flex 140View GPU Options
Memory: Slot Count: 16 DIMM slots Max Memory (1DPC): Up to 4TB 3200MT/s ECCDDR4 RDIMM/LRDIMM Supports Intel® Optane™ persistent memory 200 seriesView Memory Options
Memory Voltage: 1.2V
SATA: SATA (6Gbps) ‘ RAID 0/1/5/10 support
NVMe: NVMe’ RAID 0/1/5/10 support(VROC HW key required)View NVMe Options
Chipset: Intel®C621A
Network Connectivity: Via Slim-AIOMView AIOM Options View AOC Options
LAN: 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
USB: 2 USB 3.0port(s) (rear) 2 USB 2.0port(s) (front)
Video: 1 VGAport(s)
Serial: 1 COMport(s) (Rear)
DOM: 1 SuperDOM (Disk on Module)port(s)
TPM: 1 TPM header
BIOS Type: AMI 32MB SPI FLASH ROM
Software: SuperCloud Composer Supermicro Server Manager (SSM) Supermicro Update Manager (SUM) Supermicro SuperDoctor® 5 (SD5) Super Diagnostics Offline (SDO) Supermicro Thin-Agent Service (TAS) SuperServer Automation Assistant (SAA) New!
Power configurations: ACPI/APM Power Management
Hardware: Trusted Platform Module (TPM) 2.0 Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features: Cryptographically Signed Firmware Secure Boot Secure Firmware Updates Automatic Firmware Recovery System Lockdown
FAN: Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors
Temperature: Monitoring for CPU and chassis environment Thermal Control for fan connectors
CPU: Monitors for CPU Cores, Chipset Voltages, Memory. 8 Phase-switching voltage regulator
Form Factor: 1U Rackmount
Model: CSE-LB16TS-R860AWP
Height: 1.7″ (43 mm)
Width: 17.2″ (437 mm)
Depth: 23.5″ (597 mm)
Package: 7.7″ (H) x 23.7″ (W) x 31.8″ (D)
Weight: Gross Weight: 40 lbs (18.14 kg) Net Weight: 25 lbs (11.34 kg)
Available Color: Black
LED: Device Activity LAN 1 Activity LAN 2 Activity Power status System information
Buttons: Power On/Off UID button
PCI-Express (PCIe) Configuration: Default2 PCIe 4.0 x16 FHHL slot(s) 2 PCIe 4.0 x16 AIOM slot(s) (OCP 3.0 compatible)View AOC Options
Drive Bays Configuration: Default: Total 10 bay(s)10 front hot-swap 2.5″ NVMe*/SAS*/SATA drive bay(s)(*NVMe/SAS support may require additional storage controller and/or cables, please see the optional parts list for details)View NVMe Options View Drive Options
M.2: 2 M.2 PCIe 3.0 x2 NVMe slot(s) (M-key 2280(default)’ VROC required for RAID)View M.2 Options
Fans: 6x 4cmheavy duty fans with optimal fan speed control
Air Shroud: 2 Air Shroud(s)
ROHS: RoHS Compliant
Environmental Spec.: Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (Non-Condensing) Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Key Applications
- Web Server, Firewall Application
- Data Center Optimized, Value IaaS
- Cloud Computing, Compact Server
- DNS &’ Gateway Servers, Firewall Application
- CDN, Edge Nodes
Key Features
- Dual sockets P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors
- Intel® C621A Chipset
- 16 DIMMs up to 6TB 3DS ECC DDR4-3200: LRDIMM/RDIMM/Intel® Intel® DCPMM
-
- 2 PCIe 4.0 x16 FHHL’
- 2 PCIe 3.0 x2 NVMe M.2
- Dual AIOM (OCP 3.0) slots with NCSI for networking, 1 dedicated IPMI LAN
- 10x 2.5″ hot-swap hybrid NVMe/SATA/SAS drive bays
- 6 counter-rotating 4 cm PWM fans with optimal fan speed control, 2 air shrouds
- 860W redundant Platinum level 100-240Vac and 200-240 Vdc power supplies
- 1 VGA, 1 COM, 2 USB 3.0 (rear), 2 USB 2.0 (front)
Part Number | Qty | Description |
BTR-CV3108-1U1 | 1 | CacheVault for Broadcom 3108 with mount for 1U 40 cm fan slot. (Note: It will replace one fan and lower overall system cooling) |
BTR-TFM8G-LSICVM02 | 1 | CacheVault for Broadcom 3108 (requires a mount) |
CBL-SAST-1260-100 | 1 | MiniSAS HD x8 (LE) to 2x Slimline x4 (STR) 60CM |
AOC-S3108L-H8IR-16DD | 1 | Standard LP 8 internal ports (12Gb/s) Gen-3 16HDD RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3808L-L8IT |
1 | Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA |
CBL-SAST-1276F-100
|
1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
AOC-S3816L-L16IT | 1 | Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA |
CBL-SAST-1265F-100
|
1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM |
CBL-SAST-1276F-100
|
1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
AOC-S3908L-H8IR-16DD |
1 | Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1276F-100
|
1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
BTR-CVPM05 | 1 | CacheVault for Broadcom 3908/3916 (requires a mount) |
AOC-S3916L-H16IR-32DD |
1 | Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1265F-100
|
1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM |
CBL-SAST-1276F-100
|
1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
AOC-A25G-i4SM | - | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 |
AOC-A25G-m2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX |
AOC-ATG-i2SM | - | OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2 |
AOC-A25G-i2SM | - | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 |
AOC-A25G-b2SM |
- | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2 |
AOC-A100G-b2CM |
- | OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508 |
AOC-AG-i2M |
- | OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2 |
AOC-AG-i4M |
- | OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4 |
AOC-AG-i4SM |
- | OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4 |
AOC-AH25G-m2S2TM |
- | OCP 3.0 AIOM 2x 25GbE SFP28 &' 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN &' Intel® X550-AT2 |
AOC-ATG-b2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416 |
AOC-ATGC-i2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2 |
AOC-ATG-i2T2SM |
- | OCP 3.0 AIOM 4x 10GbE RJ45 &' SFP+ PCIe x8 Intel® X710-TM4 |
AOC-ATG-i2TM |
- | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2 |
AOC-ATG-i4SM | - | OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1 |
MCP-290-00152-0N
|
1 | 1U Supermicro Cable Management Arm 2nd Gen |
MCP-240-00127-0N | 1 | CacheVault mounting tray for 2.5" drive bay |
MCP-240-00203-0N | 1 | CacheVault mounting bracket for PCIe slot |
MCP-240-21747-0N | 1 | CacheVault mounting card for AIOM slot |
FAN-0163L4
|
6 | 40x40x56 mm 23.3K-20.3K RPM Counter-rotating Fan |
MCP-280-00033-0N | 1 | Universal Thermal sensor kit with 80cm I2C cable |
SFT-DCMS-SINGLE
|
1 | Supermicro System Managment Software License |
SFT-SDDC-SINGLE | 1 | Supermicro Data Center Monitor License |
AOC-SLG3-2SM2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 SATA Modules RAID 0,1 |
AOC-SLG3-2M2 |
- | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules |
AOC-SLG4-2H8M2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0,1 |
AOC-SLG3-2NM2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules RAID 0,1 |
CBL-PWEX-1099-34 | 1 | FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM |
CBL-KIT-120C-TN10R-10 | 1 |
Enables 10 NVMe drive bays. Kit includes:
4x CBL-SAST-1219LP-85 (bay # 0-3, 6-9) 1x CBL-SAST-1234FLP-85 (bay # 4-5) |
PWS-1K27A-1R
|
2 | 1200W Redundant Titanium Level Power Supply |
AOM-TPM-9670V-S-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor |
AOM-TPM-9670V | 1 | SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor |
AOM-TPM-9672V |
1 | SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor |
AOM-TPM-9672V-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor |
AOC-VROCSTNMOD |
1 | Intel VROC Standard RAID 0, 1, 10 |
AOC-VROCPREMOD |
1 | Intel VROC Premium RAID 0, 1, 5, 10 |