Hyper A+ Server AS -2115HS-TNR

Key Applications

  • Virtualization
  • Software-defined Storage
  • AI Inference and Machine Learning
  • Cloud Computing
  • Enterprise Server

Key Features

  1. Single 4th Generation AMD EPYC™ 9004 Series Processor
  2. 24 DIMM (2 DPC) Up to 6TB ECC DDR5 RDIMM with single CPU
    • Flexible networking options with 1 AIOM networking slot (OCP NIC 3.0 compatible)
    • Configuration Options for up to’
    • 4 PCIe 5.0 x16 Slots OR’
    • 8 PCIe 5.0 x8 Slots or’
    • 3 PCIe 5.0 x16 Slots + 2 PCIe 5.0 x8 Slots or’
    • 2 PCIe 5.0 x16 Slots + 4 PCIe 5.0 x8 Slots or’
    • 1 PCIe 5.0 x16 Slots + 6 PCIe 5.0 x8 Slots
  3. 1600W Redundant Power Supplies  (Titanium Level)
  4. 2 On-board NVMe M.2 slots’ 1x PCIe 3.0 x4, 1x PCIe 3.0 x2′ 80mm/110mm (Boot)

CPU: Single Socket SP5 AMD EPYC™ 9004 Series Processors
Core Count: Up to 128C/256T
Note: Supports up to 400W TDP CPUs (Air Cooled)* *Air Cooled CPUs with TDP over 290W only supported under specific conditions. Contact a Supermicro representative for details.
Max GPU Count: Up to 2 double-width GPU(s)
Supported GPU: NVIDIA PCIe: RTX A6000, RTX 6000 Ada GenerationView GPU Options
CPU-GPU Interconnect: PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect: PCIe
Memory: Slot Count: 24 DIMM slots Max Memory (1DPC): Up to 3TB 4800MT/s ECCDDR5 RDIMM Max Memory (2DPC): Up to 6TB 4000MT/s ECCDDR5 RDIMMView Memory Options
Memory Voltage: 1.1V
Chipset: System on Chip
Network Connectivity: Via AIOMView AIOM Options View AOC Options
LAN: 1 RJ45 1 GbE Dedicated IPMI LAN port(s)
USB: 2 USB 3.0port(s) (rear)
Video: 1 VGAport(s)
BIOS Type: AMI 32MB SPI Flash EEPROM
BIOS Features: ACPI 6.4 Plug and Play (PnP) SMBIOS 3.5 or later UEFI 2.8 USB Keyboard support
Software: SuperCloud Composer Supermicro Server Manager (SSM) Supermicro Update Manager (SUM) Supermicro SuperDoctor® 5 (SD5) Super Diagnostics Offline (SDO) Supermicro Thin-Agent Service (TAS) SuperServer Automation Assistant (SAA) New!
Power configurations: ACPI Power Management Power-on mode control for AC power loss recovery Power button override mechanism,
Hardware: Trusted Platform Module (TPM) 2.0 Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features: Cryptographically Signed Firmware Secure Boot Secure Firmware Updates Automatic Firmware Recovery Supply Chain Security: Remote Attestation Runtime BMC Protections System Lockdown
FAN: Fans with tachometer monitoring Status monitor for speed control Pulse Width Modulated (PWM) fan connectors
Temperature: Monitoring for CPU and chassis environment Thermal Control for fan connectors
Voltage: System temperature, Memory temperature, CPU temperature, 3.3V standby, +5V standby, +5V, +3.3V, +12V, CPU thermal trip support
Form Factor: 2U
Model: CSE-HS219-R1K63P-A
Height: 3.5″ (88.9 mm)
Width: 17.2″ (437 mm)
Depth: 29.9″ (760 mm)
Package: 10.4″ (H) x 23.8″ (W) x 43.6″ (D)
Weight: Gross Weight: 72 lbs (32.7 kg) Net Weight: 39 lbs (17.7 kg)
Available Color: Black front & silver body
LED: HDD activity LAN1 activity Power status System information
Buttons: Power On/Off UID button
PCI-Express (PCIe) Configuration: Default1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option A*1 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option B*2 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option C*2 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option D*1 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 2 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option E*4 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option F*4 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option G*3 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 2 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option H*2 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 4 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) Option I*1 PCIe 5.0 x16 (in x16) FHFL double-width slot(s) 6 PCIe 5.0 x8 (in x16) FHFL slot(s) 1 PCIe 5.0 x16 AIOM slot(s) (OCP 3.0 compatible) (*Requires additional parts, please see the optional parts list for details. For more details on PCIe slot configuration options, please refer to the system callout images above.)…View AOC Options
Drive Bays Configuration: Default: Total 24 bay(s)24 front hot-swap 2.5″ NVMe*/SAS*/SATA* drive bay(s)(*NVMe/SAS/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)View NVMe Options View Drive Options
M.2: 1 M.2 PCIe 3.0 x4 NVMe slot(s) (M-key 22110(default)/2280) 1 M.2 PCIe 3.0 x2 NVMe slot(s) (M-key 22110(default)/2280)View M.2 Options
Fans: 4x 8cmheavy duty fans with optimal fan speed control
Air Shroud: 1 Air Shroud(s)
Environmental Spec.: Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing)
Recycle: Return Server-End of Life Product

Part Number Qty Description

AOC-S3816L-L16iT

OR
AOC-S3916L-H16iR
CBL-SAST-1264F-100
CBL-SAST-1276F-100
1
1
1
1
16 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD
16 int 12Gb/s ports, x8 Gen4, ROC - LP, 240 HDD
Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM
Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,76/76CM
MCP-220-21602-0B 1 Black 2.5" HDD dummy cover for 8 HDD, Hex hole
CBL-CDAT-1062

1 i2C Y cable (1x4 to 2x 1x4),45cm,26AWG
MCP-220-00185-0N 2 Dummy cover for two 2.5" drive bays
CBL-MCIO-1245M5-Z 1 MCIO x8 (STR to STR),45cm,30AWG
CBL-MCIO-1340M5R 1 MCIO x8 (STR to RA),40CM,32AWG
CBL-GNZ4-1265M5Y-X 1 GENZ 4C to 2 MCIO x8,STR,65/65cm,30AWG
CBL-MCIO-1255M5

1 MCIO x8 (STR to STR),55CM,30AWG
CBL-MCIO-1250M5-Z

2 MCIO x8 (STR to STR),50cm,30AWG
CBL-MCIO-1260M5

1 MCIO (x8 STR to x8 STR),60CM,30AWG,85OHM
CBL-MCIO-1330M5 1 MCIO (x8 to x8), STR, 30cm,G5,32AWG
CBL-MCIO-1326M5

1 MCIO (x8 to x8), STR, 26cm,G5,32AWG
CBL-MCIO-1340M5R 1 MCIO x8 (STR to RA),40CM,32AWG
AOC-S3808L-L8iT OR
AOC-S3908L-H8iR
CBL-SAST-1296F-100
1
1
1
8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD
8 int 12Gb/s ports, x8 Gen4, ROC - LP, 240 HDD
Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,96/96CM
CBL-MCIO-1255M5

1 MCIO x8 (STR to STR),55CM,30AWG
CBL-MCIO-1326M5

1 MCIO (x8 to x8), STR, 26cm,G5,32AWG
CBL-MCIO-1330M5 1 MCIO (x8 to x8), STR, 30cm,G5,32AWG
CBL-MCIO-1260M5

1 MCIO (x8 STR to x8 STR),60CM,30AWG,85OHM
CBL-MCIO-1245M5-Z 1 MCIO x8 (STR to STR),45cm,30AWG
CBL-GNZ4-1265M5Y-X 1 GENZ 4C to 2 MCIO x8,STR,65/65cm,30AWG
CBL-MCIO-1250M5-Z

2 MCIO x8 (STR to STR),50cm,30AWG
CBL-GNZ4-1265M5Y-X 1 GENZ 4C to 2 MCIO x8,STR,65/65cm,30AWG
CBL-MCIO-1340M5R 1 MCIO x8 (STR to RA),40CM,32AWG
CBL-MCIO-1260M5

1 MCIO (x8 STR to x8 STR),60CM,30AWG,85OHM
CBL-MCIO-1245M5-Z 1 MCIO x8 (STR to STR),45cm,30AWG
CBL-MCIO-1218M5-1

1 MCIO x8 (STR to STR),18CM,85OHM
CBL-MCIO-1221M5

1 MCIO x8 (STR to STR),21cm
CBL-MCIO-1250M5-Z

2 MCIO x8 (STR to STR),50cm,30AWG
CBL-MCIO-1326M5

1 MCIO (x8 to x8), STR, 26cm,G5,32AWG
CBL-MCIO-1255M5

1 MCIO x8 (STR to STR),55CM,30AWG
CBL-MCIO-1330M5 1 MCIO (x8 to x8), STR, 30cm,G5,32AWG
I2C Cable
CBL-CDAT-1062


1

i2C Y cable (1x4 to 2x 1x4),45cm,26AWG
Last 8 SAS Support
AOC-S3808L-L8iT OR
AOC-S3908L-H8iR
CBL-SAST-1296F-100

1
1
1

8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD
8 int 12Gb/s ports, x8 Gen4, ROC - LP, 240 HDD
Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,96/96CM
First 16 SAS Support

AOC-S3816L-L16iT

OR
AOC-S3916L-H16iR
CBL-SAST-1264F-100
CBL-SAST-1276F-100

1
1
1
1

16 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD
16 int 12Gb/s ports, x8 Gen4, ROC - LP, 240 HDD
Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM
Slimline x8 (LE) to 2x Slimline x4 (STR),FFC,76/76CM
MCP-220-21602-0B 1 Black 2.5" HDD dummy cover for 8 HDD, Hex hole
CBL-CDAT-1062

1 i2C Y cable (1x4 to 2x 1x4),45cm,26AWG
CBL-MCIO-1223S4Y 1 MCIO x8 to 2 SlimSAS x4, STR, 23cm, 85Ohm
CBL-MCIO-1275S4Y 1 MCIO x8 to 2 SlimSAS x4, STR, 75cm, 85Ohm
CBL-MCIO-1255S4Y

1 MCIO x8 to 2 SlimSAS x4, STR, 55cm, 30AWG
MCP-290-21907-0N 1 Hyper 2U rear handle kit for immersion cooling
MCP-220-21602-0B
OR
MCP-220-00185-0N
- Dummy cover for eight 2.5" drive bays

Dummy cover for two 2.5" drive bays
MCP-240-21108-0N 1 Riser Bracket(2-slot) for RSC-H-68G5
RSC-H-68G5 1 1U LHS Hyper Riser card with two PCIe 5.0 slots
CBL-PWEX-1136YB-25 1 MicroHi(2x4 to 2x2Y),PH3.0,25/25cm,8.5A/p,18AWG
CBL-MCIO-1245M5R 1 MCIO x8 (RA to STR),45cm,30AWG
CBL-MCIO-1335M5R 1 MCIO x8 (RA to STR),35CM,32AWG
LBL-4000 1 Cabled PCIe Slot 2 Warning Label
CBL-MCIO-1245M5-Z 1 MCIO x8 (STR to STR),45cm,30AWG
CBL-MCIO-1245M5R 1 MCIO x8 (RA to STR),45cm,30AWG
CBL-PWEX-1136YB-25 1 MicroHi(2x4 to 2x2Y),PH3.0,25/25cm,8.5A/p,18AWG
RSC-H-68G5 1 1U LHS Hyper Riser card with two PCIe 5.0 slots
MCP-240-21108-0N 1 Riser Bracket(2-slot) for RSC-H-68G5
CBL-GNZ4-1227M5YRR16 1 GENZ 4C STR to 2 MCIO x8 RA/RA 27/16cm
CBL-PWEX-1136YB-25 1 MicroHi(2x4 to 2x2Y),PH3.0,25/25cm,8.5A/p,18AWG
LBL-4000 1 Cabled PCIe Slot 4 Warning Label
MCP-120-82927-0N 1 Middle riser support bracket
MCP-240-21108-0N 1 Riser Bracket(2-slot) for RSC-H-68G5
RSC-H-68G5 1 1U LHS Hyper Riser card with two PCIe 5.0 slots
CBL-GNZ4-1227M5YR21 1 GENZ 4C STR to 2 MCIO x8 STR/RA 27/21cm
CBL-PWEX-1136YB-25 1 MicroHi(2x4 to 2x2Y),PH3.0,25/25cm,8.5A/p,18AWG
MCP-120-82927-0N 1 Middle riser support bracket
MCP-240-21108-0N 1 Riser Bracket(2-slot) for RSC-H-68G5
RSC-H-68G5 1 1U LHS Hyper Riser card with two PCIe 5.0 slots
CBL-MCIO-1245M5-Z 2 MCIO x8 (STR to STR),45cm,30AWG
LBL-4000 1 Cabled PCIe Slot 6 Warning Label
MCP-240-21908-0N 1 Riser Bracket(4-slot)
RSC-H2-6888G5L 1 2U LHS Hyper Riser card with 4 PCIe 5.0 slots
CBL-MCIO-1245M5R 1 MCIO x8 (RA to STR),45cm,30AWG
CBL-MCIO-1335M5R 1 MCIO x8 (RA to STR),35CM,32AWG
CBL-PWEX-1136YB-25 1 MicroHi(2x4 to 2x2Y),PH3.0,25/25cm,8.5A/p,18AWG
LBL-4000 1 Cabled PCIe Slot 6 Warning Label
MCP-240-21908-0N 1 Riser Bracket(4-slot)
RSC-H-68G5 1 1U LHS Hyper Riser card with two PCIe 5.0 slots
RSC-H-6G5L 1 1U LHS Hyper riser card with one PCIe 5.0 X16 slot
CBL-MCIO-1245M5-Z 2 MCIO x8 (STR to STR),45cm,30AWG
MCP-240-21908-0N 1 Riser Bracket(4-slot)
RSC-H2-6888G5L 1 2U LHS Hyper Riser card with 4 PCIe 5.0 slots
RSC-H-6G5L 1 1U LHS Hyper riser card with one PCIe 5.0 X16 slot
MCP-240-21908-0N 1 Riser Bracket(4-slot)
LBL-4000 2 Cabled PCIe Slot 5/6 Warning Label
RSC-H2-6888G5L 1 2U LHS Hyper Riser card with 4 PCIe 5.0 slots
MCP-240-21908-0N 1 Riser Bracket(4-slot)
MCP-290-21103-0N 1 21.65" ball-bearing rail set for Hyper servers
MCP-290-11903-0N

(included in the system )
1 30.5" ball-bearing rail set for Hyper servers
MCP-290-11902-0N 1 35.25" ball-bearing rail set for Hyper servers
MCP-290-11901-0N 1 41" ball-bearing rail set for Hyper servers
CBL-0010L

1 9-Pin 26CM Serial Port DTK Cable with PCIe Bracket
AOM-TPM-9672V-FIPS 1 AOM-TPM-9672V-FIPS TPM 2.0 with 10 pins SPI support FIPS
AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller' vertical form factor
AOM-TPM-9670H-FIPS 1 AOM-TPM-9670H-FIPS supporting FIPS 140-2,RoHS

AOM-TPM-9672V

1 AOM-TPM-9672V- TPM 2.0 with 10 pins SPI,RoHS