X10SLE-F

MBD-X10SLE-F: X10SLE-F
Form Factor: Proprietary
Dimensions: 4.6″ x 11.7″ (11.68cm x 29.72cm)
CPU: Intel® 4th Generation Core™ i3 series, Intel® Celeron®, Intel® Pentium®v, Intel® Xeon® processor E3-1200 v3, Intel® Xeon® Processor E3-1200 v4 series.Single Socket LGA 1150 supported
Memory Capacity: Up to 32GB Unbuffered ECC UDIMM, DDR3-1600MHz, in 4 DIMM slots 4x 240-pin DDR3 DIMM sockets
Memory Type: 1600MHz ECC DDR3 SDRAM 72-bit, 240-pin gold-plated DIMMs
DIMM Sizes: 2GB, 4GB, 8GB
Memory Voltage: 1.5V
Error Detection: Corrects single-bit errorsDetects double-bit errors (using ECC memory)
Chipset: Intel® C224 Express PCH
SATA: Intel® C224 controller for 4 SATA3 (6 Gbps) ports’ RAID 0,1,5,10
IPMI: Support for Intelligent Platform Management Interface v.2.0IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Network Controllers: 1 Realtek RTL8211E PHY (dedicated IPMI)
Graphics: Aspeed AST2400 BMC via KVM connector
SATA: 4 SATA3 (6Gbps) port
LAN: 1 RJ45 Dedicated IPMI LAN port
USB: 2 USB 2.0 via KVM connector
Video Output: 1 VGA port,via KVM connector
Serial Port / Header: 1 COM Port (1 rear), via KVM connector
TPM: 1 TPM Header
PCI-E: 1 PCI-E 3.0 x8 (Micro Low Profile)for Dual GbE, 10GbE or IB AOC
BIOS Type: 128Mb SPI Flash EEPROM with AMI BIOS
BIOS Features: DMI (SMBIOS) 2.7ACPI 5.0USB Keyboard support
Software: IPMI (Intelligent Platform Management Interface) v2.0 with KVM support, IPMI2.0, KVM with dedicated LAN, NMI, SuperDoctor® III, Watchdog
Power Configurations: ACPI Power ManagementMain Switch Override MechanismPower-on mode for AC power recoveryInternal/External modem ring-on
Voltage: +1.8V, +12V, +3.3V, +5V, +5V standby, 3.3V standby, 5 Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V, Chipset Voltage, HT, Monitors CPU voltages, VBAT
FAN: 5x 4-pin fan headers (up to 5 fans), 5 fans with tachometer status monitoring, Low noise fan speed control, Pulse Width Modulated (PWM) fan connectors, Status monitoring for on/off control, Status monitoring for speed control, Support 3-pin fans (w/o speed control)
Temperature: Monitoring for CPU and chassis environment, CPU thermal trip support, FC temperature sensing logic, Thermal Monitor 2 (TM2) support, PECI
LED: CPU / System Overheat LED, UID/Remote UIDBMC Heartbeat LED, System Failure LED
Other Features: ACPI power management, CPU thermal trip support for processor protection, RoHS, System level control, UID, WOL
Operating Temperature Range: 0°C ~ 50°C (32°F ~ 122°F)
Non-Operating Temperature Range: -40°C — 70°C (-40°F — 158°F)
Operating Relative Humidity Range: 8% — 90% (non-condensing)
Non-Operating Relative Humidity Range: 5% — 95% (non-condensing)

Server Name

SYS-5038ML-H12TRF